Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 7134   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 
ORIGINAL ARTICLE
Year : 2013  |  Volume : 16  |  Issue : 2  |  Page : 253-257

Effects of user experience and method in the inflation of endotracheal tube pilot balloon on cuff pressure


Anesthesiology and Reanimation Department, Firat University, Faculty of Medicine, Elazig, Turkey

Correspondence Address:
A B Ozer
Anesthesiology and Reanimation Department, Firat University, Faculty of Medicine, Elazig
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1119-3077.110139

Rights and Permissions

Context: Endotracheal tube cuff pressure (ETCP) is recommended to be maintained between 20-30 cm H2O limits. While insufficient inflation of ETC may cause aspirations, over-inflation of it may lead to damage in tracheal epithelium. Aims: We planned to investigate the effects of user experience and cuff pressure inflation method differences following endotracheal tube cuff pressure and complaints about it. Patients and Methods: Two hundred and fifty patients planned for general anaesthesia were included in this study. ETC was inflated by users with different experience according to leakage or pilot balloon palpation techniques. ETCPs were measured by manometer at three periods (5 and 60 minutes after endotracheal intubation, and before extubation). Complaints about it were recorded in post anaesthetic care unit and 24 hours postoperatively. Results: Though we found experience of user had significant effect on the ETCP regulations, we observed inflation methods did not have any effect. However we found ETCP was higher than normal range with experienced users. A correlation was observed between cuff pressure and anaesthesia duration with postoperative complaints. Conclusions: Our study concluded that the methods used do not have any significant advantage over one another. While ETC inflated at normal pressure increases as user's experience increases, experience alone is not enough in adjusting ETCP. A manometer should be used in routine inflation of ETC instead of conventional methods. CP and anaesthesia duration have correlations with some postoperative complaints.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2470    
    Printed85    
    Emailed1    
    PDF Downloaded569    
    Comments [Add]    
    Cited by others 7    

Recommend this journal