ORIGINAL ARTICLE
Year : 2015  |  Volume : 18  |  Issue : 5  |  Page : 584-588

Blood pressure values in healthy term newborns at a tertiary health facility in Enugu, Nigeria


1 Department of Paediatrics, Federal Teaching Hospital, Abakiliki, Ebonyi State, Nigeria
2 Department of Paediatrics, Enugu State University Teaching Hospital, Enugu, Nigeria
3 Department of Paediatrics, UNTH, Ituku Ozalla, Enugu, Nigeria
4 Department of Paediatrics, Royal Victoria Infirmary, Newcastle, United Kingdom

Date of Acceptance25-Mar-2015
Date of Web Publication22-Jun-2015

Correspondence Address:
I C Nwokoye
Department of Pediatrics, Federal Teaching Hospital, Abakaliki, Ebonyi State
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1119-3077.158944

Rights and Permissions
   Abstract 

Background: Blood pressure (BP) is a reflection of hemodynamic variables. It is an important vital sign and indicator of clinical stability. Accurate measurement of this physiological signal is essential for the optimal management of the ill infant. An increase in the awareness of hypertension among neonates has resulted to increased ability to diagnose neonates with the disease.
Objectives: This study aimed to determine BP values in apparently healthy term newborns in the first 48 h of life and evaluate the factors affecting BP at birth.
Methods: Three hundred and ten healthy appropriate for gestational age term newborns were consecutively recruited. BP measurements were determined using the oscillometric technique with the neonate supine after an appropriate size cuff was applied on the right arm. The monitor (Dinamap 8100) is switched on while the cuff inflation and deflation is automatically done by the instrument with subsequent display of the BP values on the screen. BP measurements were taken at age 0-24 h and 25-48 h. Their weight was measured with infant's weighing scale, and data analyzed with SPSS version 15.
Results: The mean systolic BP (SBP), diastolic and mean arterial BP at 0-24 h were 63.3 ± 5.5 mmHg, 36.8 ± 5.3 mmHg and 46.4 ± 5.2 mmHg respectively. There was a positive correlation between birth weight and SBP at birth. No significant correlation was found between BP and gender, mode of delivery or maternal age.
Conclusion: This study provides current normative BP values that can be used in neonatal Intensive Care Unit.

Keywords: Blood pressure, healthy, newborns, term


How to cite this article:
Nwokoye I C, Uleanya N D, Ibeziako N S, Ikefuna A N, Eze J C, Ibe J C. Blood pressure values in healthy term newborns at a tertiary health facility in Enugu, Nigeria. Niger J Clin Pract 2015;18:584-8

How to cite this URL:
Nwokoye I C, Uleanya N D, Ibeziako N S, Ikefuna A N, Eze J C, Ibe J C. Blood pressure values in healthy term newborns at a tertiary health facility in Enugu, Nigeria. Niger J Clin Pract [serial online] 2015 [cited 2019 Nov 21];18:584-8. Available from: http://www.njcponline.com/text.asp?2015/18/5/584/158944


   Introduction Top


Blood pressure (BP) is a reflection of hemodynamic variables - cardiac output and peripheral vascular resistance. It is an important vital sign and an indicator of clinical stability. [1] In neonatal Intensive Care Unit (NICU), accurate monitoring of these physiological signals (BP, pulse rate, and respiratory rate) is essential for the optimal management of ill infants. BP readings considered to be abnormal have important implications and may form the basis for further investigations of other systems that are associated with alterations in the BP level. [2]

Currently, there is an increased awareness of hypertension in modern NICU as a result of increased ability to diagnose neonates with the disease. [3]

Routine BP measurement though a common clinical practice among adult physicians, is not usually observed in the pediatric practice especially in the well newborn. This may be due to the relatively low incidence of hypertension in the pediatric age group. [4] Indirect BP measurement was not routinely done in newborn infants before the development of oscillometric technology. [1] This may be partly because of the recommendation that universal screening of BP in neonates was not necessary and partly due to unavailability of appropriate equipment for the measurement of neonatal BP. [5],[6] This probably, has led to the paucity of normative data and standard BP values for neonates and infants. Reliable diastolic blood pressure (DBP) recording has been documented only for the Dinamap oscillometric unit. [7] The accuracy of the instrument meets the standard (i.e., mean error of ±5 mmHg and standard deviation of 8 mmHg) proposed by the American National Standard for manual, electronic and automated instrument when compared with intra-arterial BP measurement. [8]

Blood pressure measurement is not only very important in assessing the cardiovascular status of the newborn but is also important in the fetal origin of the cardiovascular and metabolic diseases in adulthood. [9],[10] There are genetic and hereditary predispositions to essential hypertension. This makes the early determination of BP in life imperative especially among blacks where hypertension is very common. Sadoh et al. found mean systolic BP (SBP), DBP and mean arterial pressure (MAP) of 66.8 ± 7.7, 38.5 ± 6.3 and 47.9 ± 6.3 mmHg, respectively, on day 1. However, this study cannot be used as a reference standard for appropriate for gestational age newborns as it included both small and large for gestational age neonate as well as postterm newborns. The mean of the BP values of these classes of newborns was used to generate the study's percentile chart. It has been documented that birth weight affects neonatal BP. In spite of its importance, however, there is a paucity of data on normative BP in term neonates in our environment. Such data will be very useful to the neonatologist who is faced with either hyper/or hypotension in a neonate.

The aims of this study therefore are to determine BP values in apparently healthy term newborns within the first 48 h of life, to determine factors affecting BP at birth, to correlate BP with weight and generate percentile of age/sex-specific SBP and DBP.


   Methods Top


This study was carried out at the University of Nigeria Teaching Hospital, Ituku-ozalla in Enugu, South East of Nigeria. Ethical clearance was obtained from the Ethics Committee of the hospital. Details of the study and extents of involvement of each subject were clearly explained to the mother or both parents as the case may be, and informed consent was obtained before enrolling their baby into the study.

The study was cross-sectional in which 310 healthy newborns in the postnatal ward after physical examination including modified Ballard assessment were consecutively recruited. Included were all births between 37 and 41 completed weeks of gestation as determined by maternal dates and early first trimester ultrasonography, weighing between 2.5 and 4.0 kg. All ill and asphyxiated babies, those whose mothers were on antihypertensive drugs or used illicit drugs or did not consent as well as those who have obvious cardiac or renal malformations were excluded.

Neonatal demographic data recorded included the gestational age, birth weight, mode of delivery, APGAR score at 1 and 5 min, and maternal age. BP measurement was determined using the oscillometric technique (Dinamap 8100). An appropriate size cuff was chosen after the infant's arm circumference was measured at the midpoint of the limb (between olecranon and acromion processes). This was compared with the circumference marked on the cuff to ensure that the ratio of the cuff width to arm circumference is between 0.45 and 0.70. [11] A single BP measurement was determined on each neonate with the neonate in the supine position, either awake and quiet or during sleep, after an appropriate size cuff was applied on the right arm. The newborn was left for 10-15 min after cuff application to ensure quietness. This procedure was adopted from the standard protocol for assessment of BP measurement in newborns. [12],[13] The monitor is switched on while the cuff inflation and deflation is automatically done by the instrument with subsequent display of the BP values (systolic, diastolic and MAP) on the screen. If any movement occurred during the measurement, the result was disregarded. Measurements were taken at age 0-24 h and 25-48 h. The infant's weight was measured with the baby naked using an infant's weighing scale (sensitivity − 0.05 kg, Docbel, Braun). In doing it, the baby was placed on the weighing scale, and the weight read off. The scale was checked for zero error before and after each reading.

Data analysis was done with Statistical Package for social sciences (SPSS) version 15 (Johnson and Johnson, Florida, USA). Means were calculated and compared with Student's t-test or analysis of variance where applicable. BP measurements (systolic, diastolic, and MAP) were also correlated with birth weight, gender, mode of delivery, and maternal age. Percentile charts were generated for age and sex.


   Results Top


Three hundred and ten healthy term babies were recruited in the study. This is made up of 182 (58.7%) males and 128 (41.3%) females with M: F ratio of 1.4:1. Three hundred and six subjects were singletons while four subjects were twin deliveries.

Two hundred and thirty-eight (76.8%) babies were delivered through spontaneous vertex delivery (SVD); 69 (22.3%) deliveries were by cesarean section (CS) and 3 (0.9%) by instrumental delivery (vacuum extraction). The majority of the mothers were within 21-30 years of age with mean maternal age being 29.3 ± 4.6 years [Table 1].
Table 1: Distribution of subjects by gender, mode of delivery, and maternal age


Click here to view


The mean SBP, DBP, and MAP for males in the first 24 h of life were 63.3 ± 5.7 mmHg, 36.6 ± 4.2 mmHg and 46.2 ± 5.4 mmHg, respectively. For females, the corresponding values were 63.4 ± 5.1 mmHg, 37.1 ± 4.4 mmHg and 46.6 ± 5.0 mmHg, respectively. There was no significant statistical difference observed between BP readings among males and females (P = 0.78, 0.32, 0.51 for SBP, DBP, and MAP, respectively). However, the mean values for all subjects irrespective of gender were 63.3 ± 5.5 mmHg (SBP), 36.8 ± 4.3 mmHg (DBP), and 46.4 ± 5.2 mmHg (MAP) [Table 2].
Table 2: Mean blood pressure at early post natal age by gender


Click here to view


The mean SBP, DBP, and MAP for males in the second 24 h of life were 65.5 ± 5.5 mmHg, 39.7 ± 4.6 mmHg and 49.6 ± 5.4 mmHg, respectively. In the females, the mean SBP is 65.8 ± 5.0 mmHg, mean DBP is 40.4 ± 5.0 mmHg while the mean MAP is 49.9 ± 5.5 mmHg. There was also no significant statistical difference in BP values between males and females (P = 0.61, 0.22, and 0.59, respectively, for SBP, DBP, and MAP). Overall, the mean SBP, DBP, and MAP values for all subjects irrespective of gender were 65.6 ± 5.3 mmHg, 40.0 ± 4.7 mmHg, and 49.7 mmHg, respectively.

Comparing mean SBP, DBP, and MAP between 0-24 h and 25-48 h of life, BP values at 25-48 h were higher than values at 0-24 h. The observed increase in diastolic (t = 8.84, P = 0.00) and MAP (t = 7.75, P = 0.00) were statistically significant, although the increase in mean SBP was not significant statistically (t = 1.65, P = 0.10), [Figure 1].
Figure 1: Graphic representation of the distribution of the mean systolic blood pressure, diastolic blood pressure, and mean arterial pressure values obtained at 0-24 h and 25-48 h

Click here to view


There is a positive correlation between birth weight and SBP at 0-24 h (r = 0.37, P = 0.00) and 25-48 h of life (r = 0.29, P = 0.00), and between birth weight and MAP at 25-48 h (r = 0.16, P = 0.00). There was no such correlation between DBP and birth weight as shown in [Table 3]. There was also no statistically significant correlation between maternal age, different modes of delivery, and BP values (P > 0.05) [Table 4].
Table 3: Factors affecting BP


Click here to view
Table 4: Mean BP measures for different modes of delivery and birth weight


Click here to view


The 5 th , 50 th , and 95 th percentile of BP values at 0-24 h were: SBP (54, 64, and 72 mmHg), DBP (30, 37, and 44 mmHg), and MAP (38, 46, and 55 mmHg). By 25-48 h, there was a rise in BP values such that the 5 th , 50 th , and 95 th percentile of these BP values were: SBP (57, 66, and 74 mmHg), DBP (33, 39, and 48 mmHg), and MAP (41, 49, and 60 mmHg), respectively [Figure 2]. Between 0 and 24 h of life, 22 newborns had SBP values above the 95 th percentile while 20 had values above the 95 th percentile by the 25-48 h. Nine of the 22 newborns were among those who had raised SBP by 25-48 h of life [Table 5].
Figure 2: Percentile chart of systolic blood pressure, diastolic blood pressure, and mean arterial pressure

Click here to view
Table 5: Distribution of abnormal BP values using the cut-off


Click here to view



   Discussion Top


In this study, current normative BP values of a group of healthy term newborn in the first 48 h of life are provided. This much-needed information is important in evaluating the cardiovascular system. The values in this study are comparable to that recorded within the first 36 h of life by Park and Lee, [14] and also that of Hulman et al. [1] in USA. The values are also similar to those of normal term infants recorded by Pejovic et al. [15] in Montenegro and Hwang and Chu [16] in Taiwan. The similarities between these studies may suggest that race may not affect BP in the neonate. However, the values are lower than that recorded in a previous Nigerian study. [5] The difference may be due to the study characteristics of the subjects (the study included SGA and LGA babies as well as postterm babies).

What is clear from this study is that birth weight affects BP in the early neonatal life. A significant but weak positive correlation was found between SBP and birth weight at 0-24 h and 25-48 h. There is an increase in BP in subjects with birth weight from 2.5 to 3.5 kg. However, beyond this birth weight there appears to be a plateau. This observation which is in agreement with the report of other workers may suggest that at term birth weight is a significant determinant of SBP. [14],[17],[18],[19]

The postnatal age also affected both the SBP and DBP. There was also increase in BP from day 1 to day 2. This may be due to a rise in systemic vascular resistance as the cord is clamped, and the pulmonary vascular resistance falls following lung expansion. This study agrees with the findings of Hulman et al. [1] and Zubrow et al. [20] in US, and Tan [21] in Singapore. Tan in a study of cohorts of healthy full term Asian newborn demonstrated that SBP and DBP rise in the first 3 days of life. [21] Similar rise in the first 3 days of life was also documented by Hulman et al. [1]

The mean SBP, DBP, and MAP for females were higher than that of the males both at 0-24 h and 25-48 h of life, respectively. However, these differences in mean BP values between males and females were not statistically significant. Similar findings have been documented by other workers. [5],[22] From this, it may be implied that normative values can be used interchangeably for both males and females at birth among term babies. However, although there was no statistical difference in BP on day 1 and 2, there appears to be a consistent higher BP values among the female neonates compared with the males even though the mean weight of the males was higher than the females. This finding was also noted by Gemelli et al., [22] who noted that females have higher BP values in the 1 st days of life. This finding may suggest that sex has some influence on neonatal BP.

Mode of delivery was not significantly associated with BP in this study. This is similar to the findings of Nascimento et al. [23] and Earley et al. [24] However, it differs with that of Holland and Young [25] who found that SBP was lower among CS delivered infants compared with those by SVD. It also contradicts earlier reports that the more trauma the head of a newborn passes through (e.g. during normal delivery and also during forceps delivery) the higher the BP. [25]

In the newborn, only the SBP is used to define hypertension. [4],[26] BP values ≥72 mmHg and ≥74 mmHg for 0-24 h and 25-48 h, respectively, which are the 95 th percentile values may necessitate a thorough investigation for hypertension. From this study, the newborns that developed hypertension between 0 and 24 h require only further observation, but in the second 24 h of life, subjects who still have or develop hypertension may require further investigation.


   Conclusion Top


The study provided normative BP values among full term healthy neonates in the first 48 h of life. These values are recommended for use in the evaluation of BP in newborns in our environment. There was also a positive correlation between SBP and birth weight.

 
   References Top

1.
Hulman S, Edwards R, Polansky M, Bonita Falkner B, Chen I. Blood pressure patterns in the first three days of life. J Perinatol 1991;111:231-4.  Back to cited text no. 1
    
2.
Moss AJ. Blood pressure in infants children and adolescents. West J Med 1981;134:296-314.  Back to cited text no. 2
[PUBMED]    
3.
Flynn J. Neonatal Hypertension Available from: http://www.emedcine.medscape.com/article/979558/. [Last accessed on 2009 Aug 15].  Back to cited text no. 3
    
4.
Watkinson M. Hypertension in the newborn baby. Arch Dis Child Fetal Neonatal Ed 2002;86:F78-81.  Back to cited text no. 4
    
5.
Sadoh WE, Ibhanesebhor SE. Oscillometric blood pressure reference values of African full-term neonates in their first days postpartum. Cardiovasc J Afr 2009;20:344-7.  Back to cited text no. 5
    
6.
American Academy of Pediatrics Committee on Fetus and Newborn: Routine evaluation of blood pressure, hematocrit, and glucose in newborns. Pediatrics 1993;92:474-6.  Back to cited text no. 6
    
7.
Rankova S. Blood pressure in newborn term and preterm infants. Tokai J Exp Clin Med 1989;14:181-90.  Back to cited text no. 7
    
8.
Manufacturer's Operational Manual. DINAMAP. Adult/Pediatric and Neonatal vital signs monitor model 8100. Critikon Inc. Tampa, Florida, USA.  Back to cited text no. 8
    
9.
Park MK, Menard SM. Accuracy of blood pressure measurement by the Dinamap monitor in infants and children. Pediatrics 1987;79:907-14.  Back to cited text no. 9
[PUBMED]    
10.
Barker DJ, Winter PD, Osmond C, Margetts B, Simmonds SJ. Weight in infancy and death from ischaemic heart disease. Lancet 1989;2:577-80.  Back to cited text no. 10
    
11.
Eriksson J, Forsén T, Tuomilehto J, Osmond C, Barker D. Fetal and childhood growth and hypertension in adult life. Hypertension 2000;36:790-4.  Back to cited text no. 11
    
12.
Nwankwo MU, Lorenz JM, Gardiner JC. A standard protocol for blood pressure measurement in the newborn. Pediatrics 1997;99:E10.  Back to cited text no. 12
    
13.
Sarici SU, Alpay F, Okutan V, Gökçay E. Is a standard protocol necessary for oscillometric blood pressure measurement in term newborns? Biol Neonate 2000;77:212-6.  Back to cited text no. 13
    
14.
Park MK, Lee DH. Normative arm and calf blood pressure values in the newborn. Pediatrics 1989;83:240-3.  Back to cited text no. 14
    
15.
Pejovic B, Peco-Antic A, Marinkovic-Eric J. Blood pressure in non-critically ill preterm and full-term neonates. Pediatr Nephrol 2007;22:249-57.  Back to cited text no. 15
    
16.
Hwang B, Chu NW. Normal oscillometric blood pressure values in Chinese children during their first six years. Zhonghua Min Guo Xiao Er Ke Yi Xue Hui Za Zhi 1995;36:108-12.  Back to cited text no. 16
    
17.
Sadoh WE, Ibhanesehbor SE, Monguno AM, Gubler DJ. Predictors of newborn systolic blood pressure. West Afr J Med 2010;29:86-90.  Back to cited text no. 17
    
18.
Alves JG, Vilarim JN, Figueiroa JN. Fetal influences on neonatal blood pressure. J Perinatol 1999;19:593-5.  Back to cited text no. 18
    
19.
Lee YH, Rosner B, Gould JB, Lowe EW, Kass EH. Familial aggregation of blood pressures of newborn infants and their mother. Pediatrics 1976;58:722-9.  Back to cited text no. 19
[PUBMED]    
20.
Zubrow AB, Hulman S, Kushner H, Falkner B. Determinants of blood pressure in infants admitted to neonatal intensive care units: A prospective multicenter study. Philadelphia Neonatal Blood Pressure Study Group. J Perinatol 1995;15:470-9.  Back to cited text no. 20
    
21.
Tan KL. Blood pressure in full term healthy newborns. Clin Pediatr 1987;26:21-4.  Back to cited text no. 21
    
22.
Gemelli M, Manganaro R, Mamì C, De Luca F. Longitudinal study of blood pressure during the 1 st year of life. Eur J Pediatr 1990;149:318-20.  Back to cited text no. 22
    
23.
Nascimento MC, Xavier CC, Goulart EM. Arterial blood pressure of term newborns during the first week of life. Braz J Med Biol Res 2002;35:905-11.  Back to cited text no. 23
    
24.
Earley A, Fayers P, Shinebourne EA, Sweit MD. Blood pressure in the first 6 weeks of life. Arch Dis Child 1980;55:755-7.  Back to cited text no. 24
    
25.
Holland WW, Young IM. Neonatal blood pressure in relation to maturity, mode of delivery and condition at birth. Br Med J 1956;3:1331-3.  Back to cited text no. 25
    
26.
National High Blood Pressure Education Programme Working Group on High Blood Pressure in Children and Adolescents. The fourth report on the diagnosis and treatment of high blood pressure in children and adolescents. Pediatrics 1996;98:649-58.  Back to cited text no. 26
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]


This article has been cited by
1 Heart rate variability in healthy term newborns is related to delivery mode: a prospective observational study
Marek Kozar,Ingrid Tonhajzerova,Michal Mestanik,Katarina Matasova,Mirko Zibolen,Andrea Calkovska,Kamil Javorka
BMC Pregnancy and Childbirth. 2018; 18(1)
[Pubmed] | [DOI]
2 Is birth weight associated with blood pressure among African children and adolescents? A systematic review
S. A. Lule,A. M. Elliott,L. Smeeth,E. L. Webb
Journal of Developmental Origins of Health and Disease. 2018; : 1
[Pubmed] | [DOI]
3 Hypoxic-Ischemic Encephalopathy and Therapeutic Hypothermia: The Hemodynamic Perspective
Regan E. Giesinger,Liane J. Bailey,Poorva Deshpande,Patrick J. McNamara
The Journal of Pediatrics. 2017; 180: 22
[Pubmed] | [DOI]
4 Reference values and associated factors for Japanese newborns’ blood pressure and pulse rate
Michihiro Satoh,Ryusuke Inoue,Hideko Tada,Miki Hosaka,Hirohito Metoki,Kei Asayama,Takahisa Murakami,Nariyasu Mano,Takayoshi Ohkubo,Katsuyo Yagihashi,Kazuhiko Hoshi,Masakuni Suzuki,Yutaka Imai
Journal of Hypertension. 2016; 34(8): 1578
[Pubmed] | [DOI]



 

Top
  
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Methods
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed2931    
    Printed51    
    Emailed0    
    PDF Downloaded330    
    Comments [Add]    
    Cited by others 4    

Recommend this journal