ORIGINAL ARTICLE
Year : 2017  |  Volume : 20  |  Issue : 3  |  Page : 274-277

Is 2 mm a safe distance from the inferior alveolar canal to avoid neurosensory complications in implant surgery?


Department of Oral and Maxillofacial Surgery, School of Dentistry, İstanbul Medipol University, Unkapani, Istanbul, Turkey

Correspondence Address:
G Gurler
Department of Oral and Maxillofacial Surgery, School of Dentistry, İstanbul Medipol University, Ataturk Bulvari No. 27, Unkapani, Istanbul
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1119-3077.183240

Rights and Permissions

Aim: The aim of the present study was to compare the neurosensory complications related to implants inserted closer than 2 mm to the inferior alveolar canal (IAC) with those inserted further than 2 mm. Materials and Methods: A total of 474 implants in 314 patients placed posterior to mental foramen area were evaluated retrospectively on panoramic radiographs. Patients were divided into two groups regarding implant proximity to the IAC (Group 1, distance ≤2 mm, Group 2, distance >2 mm). Postoperative neurosensory complications (pain and paresthesia) were recorded. Chi-square test was used for statistical comparison and P ≤ 0.05 was considered significant. Results: One hundred and fifty-three implants (32.2%) were inserted closer than 2 mm to the IAC whereas 321 implants (67.8%) were inserted further than 2 mm. Three implants which had a distance of 0 mm to the IAC (0.63%) caused paresthesia after surgery. Implant distance to IAC did not show a significant difference regarding pain and paresthesia (P = 0.06 and P = 0.08, respectively). Conclusion: When 2 mm is considered as a safety distance, the distance of the implants to the IAC did not yield any statistical difference regarding postoperative neurosensory complications.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1855    
    Printed52    
    Emailed0    
    PDF Downloaded163    
    Comments [Add]    

Recommend this journal