Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 801   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 21  |  Issue : 10  |  Page : 1247-1253

Digital evaluation of the dimensional accuracy of four different implant impression techniques


1 Department of Prosthodontics, Faculty of Dentistry, Baskent University, Ankara, Turkey
2 Department of Prosthodontics, Faculty of Dentistry, Near East University, Lefkosa, KKTC, Mersin 10, Turkey

Correspondence Address:
Dr. O Ozan
Department of Prosthodontics, Faculty of Dentistry, Near East University, Near East Boulevard, Mersin 10
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_284_17

Rights and Permissions

Aims: The aim of this study was to compare the dimensional accuracy of four different implant impression techniques of a mandibular edentulous model with five parallel implants. Materials and Methods: Five dental implants were placed in an edentulous mandibular model in parallel. A total of forty impressions were obtained using four different impression techniques. In Group 1 (G1) and Group 2 (G2), closed tray impressions with and without plastic caps, respectively, were used. In Group 3 (G3) and Group 4 (G4), open tray impressions with a direct splinted technique and an improved direct splinted technique, respectively, were used. All the impressions were poured with Type IV dental stone. Master model and study casts were scanned with a laser optical scanner and aligned by observing the superpositions of the anatomical landmarks using a software program. Statistical Analysis Used: Fifty measurements of the apical, coronal, and angular discrepancies of the master and study casts were obtained (n = 50) and statistically analyzed using a one-way analysis of variance and post hoc (least significant difference ) and Friedman's tests. Results: The lowest accuracy was obtained from G2 when the angular (1.48°), coronal (0.32 μm), and apical (0.14 μm) deviations were tested (P < 0.05), whereas no statistically significant differences were found among the other groups (P < 0.05). Conclusions: In cases with five parallel mandibular implants, improved accuracy was achieved using the direct splinted technique, the improved direct splinted technique, or the closed tray impression technique with snap on plastic caps.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed114    
    Printed8    
    Emailed0    
    PDF Downloaded71    
    Comments [Add]    

Recommend this journal