Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 7275   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 21  |  Issue : 12  |  Page : 1602-1606

A comparative evaluation of smear layer removal by using different Er:YAG lasers parameters: An İn-vitro scanning electron microscopic study


Department of Prosthodontics, Faculty of Dentistry, Harran University, Sanliurfa, Turkey

Correspondence Address:
Dr. Z Gorus
Department of Prosthodontics, Faculty of Dentistry, Harran University, Sanliurfa
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_317_18

Rights and Permissions

Introduction: The purpose of this in-vitro study was to investigate the effect of irrigation activation methods using different laser parameters on microhardness and push-out bonding strength of root canal dentin. This study evaluates and compares the efficacy of different laser parameters in smear layer removal using the scanning electron microscopic image analysis. Materials and Methods: In this in-vitro study, 60 newly extracted human teeth with extraction indications were used. Later, the teeth were randomly divided into three groups (n = 20). In Group 1, irrigation was performed using 2 Er:YAG laser (Fotona Laser AT Fidelis Plus III, Slovenia) with 0.6 W, 15 Hz, and 40 mJ parameters. In Group 2, irrigation was performed at 0.3 W, 15 Hz, and 20 mJ. In Group 3 (control group), conventional syringe irrigation method was performed without activation. After irrigation activation, horizontal sections were taken from the teeth, sections from the coronal, middle, and apical triplets were selected and subjected to the Vicker's microhardness test. The Kruskal–Wallis and Wilcoxon signed-rank tests were performed on the obtained data. Results: There was no statistically significant difference between the control group and the laser group (P > 0.05). As a result of the push-out bonding strength test performed on the coronal and apex regions of laser treated and untreated groups, the values of the coronal region were found to be higher than the apex region, and it was found that the bonding strength of the coronal part of the laser group was increased (P < 0.05). The change in parameters between the laser groups did not produce a statistically significant difference between the groups (P > 0.05). Conclusion: According to this study the laser group increases the bonding strength without a negative change in microhardness. In this study the further research is needed on this subject.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed610    
    Printed39    
    Emailed0    
    PDF Downloaded130    
    Comments [Add]    

Recommend this journal