Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 723   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 21  |  Issue : 12  |  Page : 1656-1661

Evaluation and comparison of the film thicknesses of six temporary cements before and after thermal cycling


1 Department of Prosthodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey
2 Nimet Bayraktar Oral and Dental Health Hospital, Kayseri, Turkey
3 Bitlis Oral and Dental Health Hospital, Bitlis, Turkey

Correspondence Address:
Dr. I L Kurtulus
Kayseri Nimet Bayraktar Oral and Dental Health Hospital, Kayseri
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_382_17

Rights and Permissions

Aim: Temporary cement can be applied for both permanent and temporary cementation of implant-supported fixed restorations. These cements must have certain physical and mechanical properties. Specifically, the film thickness directly affects the cement's clinical success. The aim of this study was to evaluate and compare the film thicknesses of six temporary cements before and after thermal cycling. Materials and Methods: Eighty-four metal copings with uniform holding loops were fabricated and divided into 12 groups of seven samples each. Six of these groups were subjected to a thermal cycling process. The copings were cemented to solid implant abutments (Implance Solid Abutment, 3.5-mm cervical diameter, 2 mm high, 6° taper, Implance Dental Implant System; AGS Medical, Trabzon, Turkey), using six different types of cement. The fitting surfaces were coated with the luting cements. After steeping in artificial saliva for 24 hours, the specimens were subjected to pull-out testing using an Instron machine. Specimens in the thermal cycling groups were subjected to 700 thermal cycles (36–55°C) prior to pull-out testing. Results: The Mann–Whitney U test revealed significant differences between the retention values of the thermal cycling (+) and thermal cycling (–) groups (U = 153.0, P < 0.01). The retention values of the groups subjected to thermal cycling were significantly lower than those of the cements that were not subjected to thermal cycling. Thermal cycling also affected the film thickness significantly (Wilcoxon signed rank test, Z = –5.533, P < 0.001). Conclusions: Thermal cycling affects the film thickness and retention of temporary cements significantly. The retention value was significantly higher for glass ionomer cement than for the other cements tested, and this cement also exhibited greatest film thickness.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed413    
    Printed5    
    Emailed0    
    PDF Downloaded101    
    Comments [Add]    

Recommend this journal