ORIGINAL ARTICLE
Year : 2019  |  Volume : 22  |  Issue : 9  |  Page : 1196-1200

The correlation of computed tomography in the evaluation of septoplasty patients


1 Department of Otorhinolaryngology, Faculty of Medical, University of Gaziantep, Gaziantep, Turkey
2 Department of Radiology, University of Gaziantep, Gaziantep, Turkey

Correspondence Address:
Dr. A Yazici
Department of Otorhinolaryngology, Faculty of Medical, University of Gaziantep, Sehitkamil 27310, Gaziantep
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_497_18

Rights and Permissions

Background: Septoplasty is one of the frequently applied nasal surgical procedures. There is still no gold standart objective method to evaluate the patients whom suffers from nasal blockage. To evaluate the septoplasty candidate with a Paranasal Computerised Tomography (PNCT) is one of the most discussed topic in the otorhinolaryngology surgical philosophy. Objectives: In this study, we aim to interpret the value of nasal valve areas measured by PNCT for both septoplasty candidates and the control population. We believe that this information could be useful for the evaluation of patients before undergoing a septoplasty procedure. Material and Methods: 600 coronal and axial tomography sections performed between May 2014 and February 2018 at the University Of Gaziantep Radiology Dept. were assessed. These tomography sections were divided into two groups called the septoplasty and the control. The septoplasty group was made up of three hundred paranasal sinus tomography images scanned before patients' septoplasty operations. The control group was created by screening 300 maxillofacial tomography's which were taken due to the suspicion of trauma at the University Of Gaziantep Emergency Clinic between May 2014 and January 2018. Results: There were 192 (64%) patients with left nasal septal deviation and 108 (36%) patients with right nasal septal deviation. The Independent Sample T-Test revealed that the mean internal nasal valve angle in the left septoplasty group was significantly lower than that of the control group (P < 0.005). A comparison of the right side nasal values revealed a significant statistical change according to the Independent Sample T-Test between the value of the right septoplasty and the control groups (P < 0.005). Conclusion: The sectional areas of nasal tomography images may show different values. However, it is still difficult to say that the clinical application of tomography images could be used as one of the indication criteria for the septoplasty procedure.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed227    
    Printed23    
    Emailed0    
    PDF Downloaded125    
    Comments [Add]    

Recommend this journal