ORIGINAL ARTICLE
Year : 2019  |  Volume : 22  |  Issue : 9  |  Page : 1276-1280

Finite element analysis on the hollow porous design at the proximal end of cementless femoral prosthesis stem


1 Department of Orthopaedics, Taixing People's Hospital, Taixing, PR China
2 Department of Orthopaedics, Jinling Clinical Medical College, Nanjing Medical University, Nanjing, Jiangsu, PR China

Correspondence Address:
Dr. S He
Department of Orthopaedics, Taixing People's Hospital, Taixing, Jiangsu
PR China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_141_19

Rights and Permissions

Aims: The present study aims to improve the design of cementless femoral prosthesis stem and achieve better bone ingrowth and long-term stability. Materials and Methods: Four models with different directional hollow holes at the proximal end of femoral prosthesis were designed and finite element analysis was applied to calculate the magnitude of conducting force within the differently angled holes and the stress distribution of the femur and prosthesis. Results: Holes in prostheses make no difference on the stress values of femoral inner walls. The conducting forces in models trepanned on the lateral plane were 6.60N (0° pore) and 8.40N (45° pore) while forces in models trepanned on the anterior-posterior planes were 0.45N (upper 0° pore), 0.48N (lower 0° pore) and 1.57N (upper 45° pore), 1.51N (lower 45° pore), respectively. Conclusion: The position and direction of hollow holes influenced the conducting force in holes but had no influence on stress values of femoral inner walls. Prostheses with one 45° hole trepanned on the lateral plane of proximal prostheses presented best in elevating conducting force.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed219    
    Printed7    
    Emailed0    
    PDF Downloaded57    
    Comments [Add]    

Recommend this journal