Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 644   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 

  Table of Contents 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 23  |  Issue : 5  |  Page : 720-728

How do the surface coating and one-year water aging affect the properties of fluoride-releasing restorative materials?


Department of Restorative Dentistry, Faculty of Dentistry, Süleyman Demirel University, Isparta, Turkey

Date of Submission30-Oct-2019
Date of Acceptance13-Jan-2020
Date of Web Publication4-May-2020

Correspondence Address:
Dr. M Ugurlu
Faculty of Dentistry, Süleyman Demirel University, East Campus, 32100, Isparta
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_591_19

Rights and Permissions
   Abstract 


Objective: To evaluate the effects of surface coating and 1-year water aging on flexural strength, compressive strength (CS) and surface roughness of fluoride-releasing restorative materials. Materials and Methods: The specimens were prepared from seven materials: GCP Glass Fill (GCP), Amalgomer CR (AHL), Zirconomer (Shofu), Fuji IX GP Capsule (GC), Beautifil II (Shofu), Estelite Σ Quick (Tokuyama), and reliaFIL LC (AHL). The specimens were randomly divided into two groups for each test: surface coated with G-Coat Plus (GC) and uncoated. Each group was subdivided into two groups stored in distilled water at 37°C for 24 h and 1 year before testing (n = 10). The flexural and CS were evaluated according to ISO standards on a universal testing machine. The surface roughness was assessed with AFM. After flexural strength test, a cross-section of the coated specimens was evaluated with SEM. Data were analyzed with one-way analysis of variance, Duncan and independent t-tests (P = 0.05). Results: After 24 h, a significant increase was observed on the flexural and CS of Amalgomer CR, Zirconomer, and Fuji IX GP by coating (P < 0.05). After 1 year, the coating increased the flexural strength of Amalgomer CR and Zirconomer, and CS of GCP Glass Fill (P < 0.05). The coating decreased the surface roughness of GCP Glass Fill, Amalgomer CR, and Zirconomer after 1 year (P < 0.05). The water aging decreased the mechanical properties of glass ionomer-based materials and increased their surface roughness (P < 0.05). Conclusion: The mechanical properties and surface roughness of glass ionomer-based materials were affected by coating and water aging.

Keywords: Compressive strength, flexural strength, glass ionomer cement, surface coating, surface roughness


How to cite this article:
Ugurlu M. How do the surface coating and one-year water aging affect the properties of fluoride-releasing restorative materials?. Niger J Clin Pract 2020;23:720-8

How to cite this URL:
Ugurlu M. How do the surface coating and one-year water aging affect the properties of fluoride-releasing restorative materials?. Niger J Clin Pract [serial online] 2020 [cited 2020 Jun 4];23:720-8. Available from: http://www.njcponline.com/text.asp?2020/23/5/720/283724




   Introduction Top


The glass-ionomer cements (GICs) have been widely used in dentistry due to their beneficial properties, such as biological compatibility, chemical adhesion to tooth structure, and especially fluoride release which contribute to caries preventive character.[1],[2] However, some characteristics of the GICs can limit their indications for clinical use.[3] The long setting reaction time and the water sensitivity during the setting reaction may cause low mechanical properties of the GICs.[4],[5] During the setting process, water has an important role for the proper maturation of GICs.[5] The initial stage, which is the clinical setting reaction, occurs within the first 10 min after mixing. The second stage, involving the release of the calcium and aluminum ions within the matrix, is a slower continuation of the acid-base reaction that lasts 24 h.[4] The material is very sensitive to water uptake at the first reaction, while the material is very susceptible to dehydration during the second step. Both water contamination and dehydration result in incomplete or inadequate maturation of GICs and thus to inferior mechanical properties.[4]

When selecting a material to restore teeth, one of the main considerations is the mechanical properties of the material.[6] The mechanical properties of a direct restorative material need to be strong enough to withstand the forces associated with mastication and other possible loading.[7] The materials must also maintain these properties for the long term.[8],[9] In laboratory conditions, the flexural and compressive strength (CS) tests are commonly used to evaluate and compare the mechanical properties of dental materials.[10],[11] Moreover, surface characteristic such as surface roughness also determines the clinical quality of restorative materials.[12] The GICs have been introduced in dental practice by Wilson and Kent in the early 1970s.[1] Since then, several researches have been done to enhance their mechanical properties and to expand their clinical applications. Consequently, fluoride-releasing and glass ionomer-based materials have been recently developed. Some of these materials are the high viscosity GIC, the ceramic reinforced GIC, the zirconia reinforced GIC, and the GIC containing calcium fluorapatite nanocrystals.[13] One of the recent developments in the fluoride-releasing restorative materials has been the introduction of giomer materials. The giomer is a hybridization material of GIC and composite resin, containing surface pre-reacted glass ionomer (S-PRG) filler particles within a resin matrix.[3]

In previous studies, the resin coating has been recommended for increasing the clinical performance of glass-ionomer restoration[14],[15] and the mechanical properties of GICs by preventing water contamination and dehydration.[16],[17],[18],[19] The coating agent acts as barriers to water, so the hardening and maturation processes of GIC can take place unaffected by water uptake and water loss.[16],[19] It has been reported that the self-adhesive resin coating agent provided a seal of the GIC's surface through high hydrophilicity and low viscosity.[20] It has been additionally stated that the coating agent could improve the mechanical properties by filling the surface micro porosities of the materials.[17] Reviewing the literature, there is little data on the mechanical properties of recently developed fluoride-releasing materials, and no information is available regarding the effect of resin coating and water aging on the mechanical properties and surface roughness of these materials.

Therefore, the objective of this study was to evaluate the effect of resin coating and 1-year water aging on the flexural strength, CS, and surface roughness of the fluoride-releasing materials. The null hypothesis tested was the resin coating and water aging would not affect the flexural strength, CS, and surface roughness of the materials.


   Materials and Methods Top


Five different fluoride-releasing restorative materials were tested in this present study. The restorative materials were a glass carbomer (GCP Glass Fill; GCP, Vianen, the Netherlands), a ceramic reinforced GIC (Amalgomer CR; Advanced Healthcare Ltd, Tonbridge, UK), a zirconia reinforced GIC (Zirconomer; Shofu, Kyoto, Japan), a high-viscosity GIC (Fuji IX GP Capsule; GC, Tokyo, Japan), and a giomer (Beautifil II; Shofu, Kyoto, Japan). As control, a nano-filled composite resin (Estelite Σ Quick; Tokuyama, Tokyo, Japan) and a nano-hybrid composite resin (reliaFIL LC; Advanced Healthcare Ltd) were used. The materials are listed in [Table 1] with the composition, manufacturer, and lot number. A nano-filled surface sealant agent (G-Coat Plus; GC, Lot: 1710031) were also tested.
Table 1: The composition of the materials according to the manufacturers' data

Click here to view


Specimen preparation

The 40 specimens were prepared from each material for each test. The dimensions of bar-shaped specimens for flexural strength test were 25 × 2 × 2 mm. The specimens for CS test were 4 mm in diameter and 6 mm in height. The specimens for surface roughness test were 5 mm in diameter and 2-mm thickness. After the material was inserted into the teflon molds, the polyester strips (Mylar strip; SS White Co., Philadelphia, PA, USA) were pressed onto the mould surfaces with glass plates to extrude excess material and obtain a flat surface. The giomer and composite resins were polymerized through the glass plate using a LED light-curing unit (Smartlite Focus; Dentsply, Milford, DE, USA) according to the manufacturer's instructions [Table 2]. The intensity of the curing light (Smartlite Focus; Dentsply, Milford, DE, USA) was measured before and after application and the light output was never <1,000 mW/cm[2]. The giomer and composite resins were placed incrementally into the mould for CS test and each 2-mm thick layer was light-cured. For GCP Glass Fill and Fuji IX GP, a capsule mixer (Silver Mix; Stomamed, Bratislava, Slovakia) was used for 10 s of mixing before application of the material. Amalgomer CR and Zirconomer were mixed within a total of 30 s according to the manufacturer's instructions [Table 2]. After the light curing and setting cycle, the specimens were removed from the molds. In order to obtain flat surface, both side of the specimens were gently polished manually with a circular motion with 1,000-grit and 1,500-grit wet silicon carbide papers. Each specimen was brief rinsed in tap water between each grit. The specimens were randomly divided into two groups for each test according to coated with G-Coat Plus and uncoated. G-Coat Plus was applied using a micro-tip applicator, and then gently air thinned for 5 s and light cured for 20 s with the LED light curing unit according to manufacturer's instructions. Only one surface of the specimens was coated as in a clinical application. All the specimens were prepared at room temperature (21 ± 1°C) in 55% relative humidity. Each group was subdivided into two groups stored in distilled water at 37°C for 24 h and 1 year before testing. The 10 specimens were tested in each subgroup (n = 10).
Table 2: The application procedures of the materials according to manufacturer instructions

Click here to view


Mechanical properties

The flexural strength was evaluated using three-point bending test according to the ISO 4049:2009 standard with a 20-mm span at a crosshead speed of 1 mm/min on a universal testing machine (Autograph AGS-X; Shimadzu, Kyoto, Japan). Before testing, the specimen dimensions were measured using a digital caliper (Digimatic Caliper, Mitutoyo, Tokyo, Japan). The flexural strength (FS) of the material was calculated by FS = 3PmaxL/(2bh[2]), where Pmax is the maximum load (N) on the load-displacement curve, L is the span length (mm), b is the width of the specimen (mm), and h is the thickness of the specimen (mm).

The CS was evaluated using the test method according to the ISO 9917-1:2007 standard. Before testing, the specimen dimensions were measured using the digital caliper. The test was carried out using the universal testing machine that had a crosshead speed of 1.0 mm/min. The specimens were placed with their flat ends between the plates of the testing machine, so the progressively increasing compressive load was applied along the long axis of the specimens. The maximum load applied to fracture the specimens was recorded. The CS of the material was calculated by CS = 4Pmax/pd[2], where Pmax is the maximum applied load (N), p = 3.14, and d is the diameter of the specimen (mm).

Surface roughness

Atomic force microscopy (AFM, ezAFM, NanoMagnetics Instruments, Ankara, Turkey) was used to determine the mean surface roughness values (Ra) of the specimens. The mean surface roughness was assessed using a Si3N4 tip with frequency of 1 Hz in contact mode. Three different areas were randomly selected with a scan area of 5 × 5 mm and resolution 512 × 512 pixels to obtain surface roughness values. The analysis of surface roughness values was done by NMI ezAFM v4.8.2.3 control software and the mean roughness value was determined for each specimen. Then, three-dimensional images were also acquired.

SEM analysis

After flexural strength test, a cross section of a specimen was randomly selected in each coated group for SEM analysis. All specimens were adhered with conductive carbon tape to aluminum stubs and observed under SEM (Quanta Feg 250, FEI, the Netherlands) with secondary electrons at × 500, ×1,000, and ×2,000 magnification by 20 kV.

Statistical analysis

Statistical analyses were performed with the SPSS Program, version 20.0 (Statistical Package for the Social Sciences; SPSS, Chicago, IL, USA). The Kolmogorov–Smirnov test was applied to verify if the data were normally distributed. The mean flexural strength, CS and surface roughness values of the material groups were compared using one-way analysis of variance and Duncan post-hoc tests. An independent t-test analyzed the differences in flexural strength, CS, and surface roughness values of the materials, evaluating the effect of coating and aging. Pearson correlation test was performed to investigate a possible correlation between the mechanical properties and surface roughness. The P value < 0.05 was considered statistically significant for all statistical analyses.


   Results Top


The flexural strength and CS values were presented in [Table 3]. The highest flexural strength and CS were obtained with Beautifil II, Estelite Σ Quick and reliaFIL LC (P < 0.05). A significant increase was observed on the flexural and CS of Amalgomer CR, Zirconomer, and Fuji IX GP after 24 h when G-Coat Plus was applied (P < 0.05). After 1 year, the coating increased the flexural strength of Amalgomer CR and Zirconomer and the CS of GCP Glass Fill (P < 0.05). The water aging significantly decreased the flexural strength of GCP Glass Fill, GCP Glass Fill Coated, Amalgomer CR Coated, Zirconomer, Fuji IX GP Coated groups (P < 0.05). The water aging significantly decreased the CS of GCP Glass Fill and Fuji IX GP Coated groups (P < 0.05).
Table 3: The mean flexural and compressive strength values (MPa) of the materials with standard deviations

Click here to view


The surface roughness values were revealed in [Table 4]. Some superficial images obtained via the contact mode of the AFM were shown in [Figure 1]a,[Figure 1]b,[Figure 1]c,[Figure 1]d,[Figure 1]e,[Figure 1]f. There were statistically differences between the surface roughness of all materials after 24 h and 1 year (P < 0.05). After 24 h, the coating did not affect the surface roughness of any materials (P > 0.05). After 1 year, a significant difference was observed on the surface roughness of GCP Glass Fill, Amalgomer CR, and Zirconomer between coated and uncoated groups (P > 0.05). The water aging significantly increased the surface roughness of all materials except the composite resins (P < 0.05). After 1 year, the highest surface roughness was obtained with GCP Glass Fill group (P < 0.05).
Table 4: The mean surface roughness values (ηm) and standard deviations of the materials

Click here to view
Figure 1: a. AFM image of the specimen in GCP Glass Fill Uncoated group after 1 year. b. AFM image of the specimen in GCP Glass Fill Coated group after 1 year. c. AFM image of the specimen in Amalgomer CR Uncoated group after 1 year. d. AFM image of the specimen in Amalgomer CR Coated group after 1 year. e. AFM image of the specimen in Zirconomer Uncoated group after 1 year. f. AFM image of the specimen in Zirconomer Coated group after 1 year. The topographical AFM 3D-images acquired in the contact mode from 5 × 5 mm area

Click here to view


The statistically significant positive correlation was observed between flexural strength (FS) and CS of the materials regardless of coating after 24 h and 1 year, whereas the statistically significant negative correlation was found between the mechanical properties and surface roughness (Ra) of the materials. The Pearson's correlation coefficient values were stated in [Figure 2]. Some SEM micrographs were presented in [Figure 3]a,[Figure 3]b,[Figure 3]c,[Figure 3]d. The SEM micrographs showed that there was a micro-mechanical interlocking between all the materials and the coating agent.
Figure 2: Pearson's correlation coefficient values for the properties of the materials. All of the correlation coefficient values displayed have statistical significance at P < 0.01 level. The statistically significant positive correlation was observed between flexural strength (FS) and compressive strength (CS) of the materials regardless of coating after 24 h and 1 year while the statistically significant negative correlation was found between the mechanical properties and surface roughness (Ra) of the materials

Click here to view
Figure 3: a. SEM photomicrograph of the cross-section of the specimen in Fuji IX GP Coated group after 24 h. b. SEM photomicrograph of the cross-section of the specimen in Fuji IX GP Coated group after 1 year. c. SEM photomicrograph of the cross-section of the specimen in Beautifil II Coated group after 24 h. d. SEM photomicrograph of the cross-section of the specimen in Beautifil II Coated group after 1 year. The photomicrographs were obtained secondary electrons mode at 20 kV. The SEM micrographs showed that there was a micro-mechanical interlocking between the material and the coating agent after 24 h and 1 year

Click here to view



   Discussion Top


In this study, the flexural strength, CS and surface roughness of the fluoride-releasing restorative materials were evaluated. The effects of surface coating and 1-year water aging on these properties of the materials were investigated. Based on the results, the surface coating and water aging influenced the properties of some fluoride-releasing materials. Therefore, the null hypothesis, that the resin coating and water aging would not affect the flexural strength, CSm and surface roughness of the materials, was partially rejected.

The setting process of GICs generally is characterized by the interaction between a polyacid liquid and a glass powder in the form of an acid-base reaction. This reaction continues by a stepwise rather long-lasting setting.[21] The changes in mechanical properties of GICs occur within the first 24 h and, the changes can be observed over several weeks or months.[5] The coating is recommended during the initial setting stage of conventional GICs for proper maturation.[5],[15] The setting process of GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP occur in form of an acid–base reaction like a conventional GIC. In the present study, the surface coating significantly increased the flexural and CS of Amalgomer CR, Zirconomer, and Fuji IX GP after 24 h. As reported in the previous studies, it could be due to the fact that the coating agent exerted control on the setting process of the materials within 24 h.[15],[19]

The protective effect of the coating from extrinsic water may allow complete maturation of the GIC reaction with delayed water exposure, thus possibly creating a stronger material while it may not reinforce the surface of the material.[19] Previous studies concluded that significant improvement of wear resistance,[16] shear punch strength,[19] and flexural strength[16],[17],[18] of Fuji IX GP after coating with G Coat Plus before water contamination. It has been also reported that the strength increases in coated GIC resulted from that the protective coating contributes to the GIC strength by improving the maturation process and not by the inherent strength of the coating layer.[15] In this study, the surface coating did not affect the flexural and CS of GCP Glass Fill after 24 h. It could result from different moisture sensitivity of GCP Glass Fill. According to the manufacturer, heat application is recommended for GCP Glass Fill during the setting reaction to increase its mechanical properties. But it has been concluded that the gloss and heat application with LED curing unit did not influence the flexural strength of GCP Glass Fill.[22] This result has been attributed to different chemical composition and moisture sensitivity of the material.[22] After 1 year, the coating increased the flexural strength of Amalgomer CR and Zirconomer, and the CS of GCP Glass Fill. As reported in a previous study, it could be due to that the coating agent reduced the surface porosity and crack propagation on the GICs.[19]

In this study, the glass ionomer-based materials GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP showed lower mechanical properties than Beautifil II and the composite resins regardless of coating and water aging. It has been previously reported that the giomer and composite resins had higher mechanical properties than GICs.[17],[23],[24],[25] In this study, the coating did not influence the mechanical properties of the giomer and composite resins. This result can be due to the high flexural and CS of the materials. It has been stated that the coating did not play a role in materials which were more resistant to flexural stresses.[16]

Water aging is one of the most widely used procedures in experimental studies to evaluate the performance of materials and simulate the physiological aging of materials.[8] It has been stated that the storage agent had a low effect on the mechanical properties; furthermore, the storage time was a more important factor.[4],[18] The water aging can cause detrimental effect on GICs based on water sorption, as it erodes the surface of the material and induces hydrolysis and dissolution of GICs' components.[26],[27] The water uptake in conventional GIC is rapid due to the hydrogel structure and large micropores on the surface; thus, a substantial decrease in strength and elasticity of the material may occur.[28] The water aging can also cause plasticization of the resin component in the composite resins due to the water sorption; therefore, the long-term storage in water can influence water sorption and consequently mechanical properties of the materials.[29] However, the effects of water aging could be related to the composition of composite resins and GICs.[7],[29]

A previous study has concluded that the flexural strength of Fuji IX GP showed an increase up to 3 months and then decreased after 6 months of water aging.[17] The improvement in the strength up to 3 months has been attributed to the acid–base reaction that proceeds slowly until final maturation completion which may take a few months.[30] It has been also stated that the storage time was an effective factor in the flexural strength of either uncoated or coated GICs.[17] In this study, the decrease in mechanical properties of GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP were observed after 1 year, but the water aging did not affect the mechanical properties of Beautifil II and the composite resins. As stated in a previous study, the result could be attributed to the water sorption of the materials.[7] The decrease of flexural strength on Zirconomer coated group and the CS on GCP Glass Fill coated group was not observed. It could be due to that the coating reduced water uptake. It has been reported that the coating with G Coat Plus could be beneficial for reducing water absorption of GIC.[31] But, in this study, the coating did not show the same effect for each glass ionomer-based material. The differences could result from different chemical composition and water uptake of the materials. Unfortunately, the water sorption was not evaluated in this study.

The surface roughness of restorative materials has a major effect on the discoloration and initial bacterial adhesion.[32] It has been stated that the increased surface roughness might be a predisposing factor to microbial colonization and cause a decrease in mechanical properties of the materials.[6],[9],[32] In this study, the negative correlation was also found between the mechanical properties and surface roughness of the materials regardless of coating and water aging. In this study, the coating did not affect the surface roughness of any materials after 24 h. The result is in agreement with a study, which concluded that the coated Fuji IX GP with G-Coat Plus showed a surface roughness similar to uncoated Fuji IX GP after 1 week.[20] In this study, the surface roughness of GCP Glass Fill, Amalgomer CR, Zirconomer, Fuji IX GP, and Beautifil II increased after 1 year. The result could be due to the water uptake of the materials. After 1 year of water aging, the microcracks could be formed on the surface of the materials. The formation of microcracks can alter the surface roughness of materials.[33] In a previous study, the microcracks on GIC surfaces were observed after aging, which could be attributed to the water uptake of glass ionomers.[8] After 1 year, the surface roughness of GCP Glass Fill, Amalgomer CR, and Zirconomer decreased by coating. As stated in a previous study, it could be due to that the coating agent reduced the surface porosity on the GICs.[19]

In this study, the SEM micrographs showed that there was still a micro-mechanical interlocking between the materials and the coating agent after 1 year, but it has been stated that the masticatory forces could cause debonding the coating agent over time in the oral environment.[15] The in vitro researches cannot exactly reflect the actual status of the oral cavity since the oral environment is dynamic and different from laboratory conditions. Besides the in vitro studies, further clinical studies are also needed to investigate the performance of the fluoride-releasing materials and the effects of resin coating.


   Conclusion Top


Within the limitations of this study, the resin coating provided valuable support for the glass ionomer-based materials, since it led to significant improvements in flexural or CS of the materials. The giomer and composite resins had higher mechanical properties than the glass ionomer-based materials. The surface roughness of any materials was not affected by the coating after 24 h, but the coating decreased the surface roughness of some of the glass ionomer-based materials after 1 year. For the glass ionomer-based materials, the 1-year water aging caused a decrease in the mechanical properties and an increase in the surface roughness.

Acknowledgements

The author thanks to Shofu Dental, GC Corporation, Dual Dental and Advanced Healthcare Ltd, for the material support of this study, and Dr. Murat KOÇ for AFM-SEM analyses, and Prof. Dr. Hikmet ORHAN for statistical analyses.

Financial support and sponsorship

The material support was provided by Shofu Dental, GC Corporation, Dual Dental and Advanced Healthcare Ltd.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Wilson AD, Kent BE. A new translucent cement for dentistry. The glass ionomer cement. Br Dent J 1972;132:133-5.  Back to cited text no. 1
    
2.
Wiegand A, Buchalla W, Attin T. Review on fluoride-releasing restorative materials--fluoride release and uptake characteristics, antibacterial activity and influence on caries formation. Dent Mater 2007;23:343-62.  Back to cited text no. 2
    
3.
Garoushi S, Vallittu PK, Lassila L. Characterization of fluoride releasing restorative dental materials. Dent Mater J 2018;37:293-300.  Back to cited text no. 3
    
4.
Nicholson JW. Maturation processes in glass-ionomer dental cements. Acta Biomater Odontol Scand 2018;4:63-71.  Back to cited text no. 4
    
5.
Ilie N. Maturation of restorative glass ionomers with simplified application procedure. J Dent 2018;79:46-52.  Back to cited text no. 5
    
6.
Xie D, Brantley WA, Culbertson BM, Wang G. Mechanical properties and microstructures of glass-ionomer cements. Dent Mater 2000;16:129-38.  Back to cited text no. 6
    
7.
Bagheri R, Azar MR, Burrow MF, Tyas MJ. The effect of aging on the fracture toughness of aesthetic restorative materials. Am J Dent 2010;23:142-6.  Back to cited text no. 7
    
8.
Zhou X, Wang S, Peng X, Hu Y, Ren B, Li M, et al. Effects of water and microbial-based aging on the performance of three dental restorative materials. J Mech Behav Biomed Mater 2018;80:42-50.  Back to cited text no. 8
    
9.
Feng J, Cheng L, Zhou X, Xu HHK, Weir MD, Li Q, et al. Effects of water aging on the mechanical and anti-biofilm properties of glass-ionomer cement containing dimethylaminododecyl methacrylate. Dent Mater 2019;35:434-43.  Back to cited text no. 9
    
10.
Yli-Urpo H, Lassila LV, Närhi T, Vallittu PK. Compressive strength and surface characterization of glass ionomer cements modified by particles of bioactive glass. Dent Mater 2005;21:201-9.  Back to cited text no. 10
    
11.
Pameijer CH, Garcia-Godoy F, Morrow BR, Jefferies SR. Flexural strength and flexural fatigue properties of resin-modified glass ionomers. J Clin Dent 2015;26:23-7.  Back to cited text no. 11
    
12.
Bagheri R, Burrow MF, Tyas MJ. Surface characteristics of aesthetic restorative materials-An SEM study. J Oral Rehabil 2007;34:68-76.  Back to cited text no. 12
    
13.
Ching HS, Luddin N, Kannan TP, Ab Rahman I, Abdul Ghani NRN. Modification of glass ionomer cements on their physical-mechanical and antimicrobial properties. J Esthet Restor Dent 2018;30:557-71.  Back to cited text no. 13
    
14.
Diem VT, Tyas MJ, Ngo HC, Phuong LH, Khanh ND. The effect of a nano-filled resin coating on the 3-year clinical performance of a conventional high-viscosity glass-ionomer cement. Clin Oral Investig 2014;18:753-9.  Back to cited text no. 14
    
15.
Lohbauer U, Krämer N, Siedschlag G, Schubert EW, Lauerer B, Müller FA, et al. Strength and wear resistance of a dental glass-ionomer cement with a novel nanofilled resin coating. Am J Dent 2011;24:124-8.  Back to cited text no. 15
    
16.
Bonifácio CC, Werner A, Kleverlaan CJ. Coating glass-ionomer cements with a nanofilled resin. Acta Odontol Scand 2012;70:471-7.  Back to cited text no. 16
    
17.
Bagheri R, Palamara J, Mese A, Manton DJ. Effect of a self-adhesive coating on the load-bearing capacity of tooth-coloured restorative materials. Aust Dent J 2017;62:71-8.  Back to cited text no. 17
    
18.
Zoergiebel J, Ilie N. Evaluation of a conventional glass ionomer cement with new zinc formulation: Effect of coating, aging and storage agents. Clin Oral Investig 2013;17:619-26.  Back to cited text no. 18
    
19.
Bagheri R, Taha NA, Azar MR, Burrow MF. Effect of G-Coat Plus on the mechanical properties of glass-ionomer cements. Aust Dent J 2013;58:448-53.  Back to cited text no. 19
    
20.
Pacifici E, Bossù M, Giovannetti A, La Torre G, Guerra F, Polimeni A. Surface roughness of glass ionomer cements indicated for uncooperative patients according to surface protection treatment. Ann Stomatol (Roma) 2014;4:250-8.  Back to cited text no. 20
    
21.
Algera TJ, Kleverlaan CJ, Prahl-Andersen B, Feilzer AJ. The influence of environmental conditions on the material properties of setting glass-ionomer cements. Dent Mater 2006;22:852-6.  Back to cited text no. 21
    
22.
Menne-Happ U, Ilie N. Effect of gloss and heat on the mechanical behaviour of a glass carbomer cement. J Dent 2013;41:223-30.  Back to cited text no. 22
    
23.
Chen S, Öhman C, Jefferies SR, Gray H, Xia W, Engqvist H. Compressive fatigue limit of four types of dental restorative materials. J Mech Behav Biomed Mater 2016;61:283-9.  Back to cited text no. 23
    
24.
Gajewski VE, Pfeifer CS, Fróes-Salgado NR, Boaro LC, Braga RR. Monomers used in resin composites: Degree of conversion, mechanical properties and water sorption/solubility. Braz Dent J 2012;23:508-14.  Back to cited text no. 24
    
25.
Walia R, Jasuja P, Verma KG, Juneja S, Mathur A, Ahuja L. A comparative evaluation of microleakage and compressive strength of Ketac Molar, Giomer, Zirconomer, and Ceram-x: An in vitro study. J Indian Soc Pedod Prev Dent 2016;34:280-4.  Back to cited text no. 25
[PUBMED]  [Full text]  
26.
Bapna MS, Gadia CM, Drummond JL. Effects of aging and cyclic loading on the mechanical properties of glass ionomer cements. Eur J Oral Sci 2002;110:330-4.  Back to cited text no. 26
    
27.
Musanje L, Shu M, Darvell BW. Water sorption and mechanical behaviour of cosmetic direct restorative materials in artificial saliva. Dent Mater 2001;17:394-401.  Back to cited text no. 27
    
28.
Cefaly DF, Franco EB, Mondelli RF, Francisconi PA, Navarro MF. Diametral tensile strength and water sorption of glass-ionomer cements used in Atraumatic Restorative Treatment. J Appl Oral Sci 2003;11:96-101.  Back to cited text no. 28
    
29.
Ricci WA, Alfano P, Pamato S, Cruz CADS, Pereira JR. Mechanical degradation of different classes of composite resins aged in water, air, and oil. Biomed Res Int 2019;2019:7410759.  Back to cited text no. 29
    
30.
Roberts HW, Berzins DW, Charlton DG. Hardness of three resin-modified glass-ionomer restorative materials as a function of depth and time. J Esthet Restor Dent 2009;21:262-72.  Back to cited text no. 30
    
31.
Hankins AD, Hatch RH, Benson JH, Blen BJ, Tantbirojn D, Versluis A. The effect of a nanofilled resin-based coating on water absorption by teeth restored with glass ionomer. J Am Dent Assoc 2014;145:363-70.  Back to cited text no. 31
    
32.
Hahnel S, Ionescu AC, Cazzaniga G, Ottobelli M, Brambilla E. Biofilm formation and release of fluoride from dental restorative materials in relation to their surface properties. J Dent 2017;60:14-24.  Back to cited text no. 32
    
33.
Swift EJ Jr, Dogan AU. Analysis of glass ionomer cement with use of scanning electron microscopy. J Prosthet Dent 1990;64:167-74.  Back to cited text no. 33
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]



 

Top
  
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed71    
    Printed0    
    Emailed0    
    PDF Downloaded39    
    Comments [Add]    