Medical and Dental Consultantsí Association of Nigeria
Home - About us - Editorial board - Search - Ahead of print - Current issue - Archives - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 2273   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 23  |  Issue : 9  |  Page : 1266-1273

Does the plasma application time affect the tensile bond strength between PMMA and a silicone-based denture liner?


1 Department of Prosthodontics, Cukurova University, Faculty of Dentistry, Adana, Turkıye
2 Department of Prosthodontics, Gazi University, Faculty of Dentistry, Ankara, Turkıye
3 Department of Chemistry, The Pennsylvania State University, University Park, Pennsylvania, USA

Correspondence Address:
Dr. E Tamam
Department of Prosthodontics, Gazi University, Faculty of Dentistry, 06510 Emek, Ankara
Turkıye
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njcp.njcp_692_19

Rights and Permissions

Aims: This study evaluated the effect of oxygen plasma and argon plasma treatments with different application times on tensile bonding of a silicone-based denture liner to polymethylmetacrylate (PMMA). Methods: Seven groups (n = 5) were prepared and six of them treated by argon plasma or oxygen plasma with 30s, 60s, and 120s, respectively; one group was left untreated served as control. After processing of denture liner, the specimens were deflasked and stored dry for 24 h, and they were then subjected to tensile bond strength testing. Differences in tensile bond strength values were determined using one-way ANOVA (α = 0.05). Results: Highest tensile bond strengths were observed in the oxygen plasma groups, followed by untreated group and argon plasma groups in turn in order. Tensile bond strenght were increased with time for both type of plasma applications tested. Conclusion: This study suggests that the adhesion between PMMA and denture liner is improved under conditions of oxygen plasma treatment with extended exposure time rather than argon plasma treatment.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed68    
    Printed0    
    Emailed0    
    PDF Downloaded32    